    Key Takeaways

    • Article 12(3) is the legal anchor; PMDA and MHLW notifications explain applicability and conformity expectations.
    • Maintenance-only connections and cloud-accessed device software can be in scope.
    • JIS T 81001-5-1:2023 mapping alone does not cover every additional Japanese conformity item.
    • Identify the maintained SBOM in relevant applications and keep it available; routine attachment is not universally required.
    • Annex F is a risk-based transitional-software approach, not another grace period.
    Direct Answer

    What cybersecurity evidence does Japan require for medical devices?

    Japan requires relevant medical devices to meet the cybersecurity provisions of Essential Principles Article 12(3). Conformity has been required after the one-year transition ended on April 1, 2024. The implementation approach uses JIS T 81001-5-1:2023 and additional MHLW conformity requirements. Prepare controlled evidence for the device, released software, operating environment, and lifecycle, with local regulatory responsibilities defined.

    Download the matching Japan cybersecurity PDF.

    This guide is for product security, engineering, and RA/QA teams preparing a Japanese market entry or maintaining an existing product. MDC Crosswalk is a companion multi-market planning resource. The PMDA and MHLW sources below are the authorities for Japanese requirements. Japanese originals prevail over reference translations.

    MHLW Notification No. 67 amended the Essential Principles with Article 12(3). PMDA's official cybersecurity register explains the April 1, 2023 effective date and one-year transition. This is not simply voluntary adoption of international guidance.

    Distinguish the binding Essential Principles from administrative notifications, Q&As, and explanatory material. The latter explain the regulator's conformity expectations; they are not all separate statutes. The applicable approval, certification, or notification pathway depends on the product. PMDA is not necessarily the reviewer for every device pathway.

    Applicability: do not stop at internet connectivity

    The provision concerns software-using medical devices connected to other devices or networks, or exposed to foreseeable unauthorized access or attack. The January 2024 Q&A, Q1, includes maintenance-only connections and cloud-accessed medical device software.

    Record these decisions:

    • Does the product use software, and what is the regulated device boundary?
    • Which interfaces connect during clinical use, installation, servicing, updates, or maintenance?
    • Can a foreseeable access or attack path affect safety or performance even without continuous internet access?
    • Which marketed configurations, companion applications, and services support intended operation?
    • Which evidence and local regulatory pathway apply to that product?

    A disconnected treatment mode is not, by itself, an exemption. Keep the applicability rationale controlled and review it when interfaces or workflows change.

    JIS T 81001-5-1 and additional conformity items

    Japan's implementation materials reference JIS T 81001-5-1:2023. The July 2023 Q&A, Q1, explains that the conformity notification also contains items not explicitly within JIS, including security-contact arrangements and customer vulnerability-disclosure procedures.

    Use the licensed Japanese standard and the current notifications for a formal assessment. An IEC checklist or certificate alone does not establish complete conformity with the Japanese Essential Principles. Our IEC security lifecycle evidence table is a planning aid, not a substitute for the JIS text or Japanese requirements.

    Evidence adaptation table

    The artifact examples below are practical working records. Their names are not a universal list of mandatory application attachments.

    Evidence areaJapan-specific adaptationManufacturer responsibility
    Product boundary and architectureDocument Article 12(3) applicability, service interfaces, cloud dependencies, and marketed configurationsEngineering / RA/QA agree the scope and pathway
    Security lifecycleMap controlled procedures and evidence to JIS and additional conformity-notification itemsEngineering and QA maintain procedures and approvals
    Threat and security risk analysisLink threats, controls, testing, residual risk, and safety consequences where relevantProduct security prepares evidence; authorized manufacturer accepts risk
    Component inventory / SBOMIdentify the controlled SBOM reference, required coverage/fields, maintenance, and availabilityConfiguration management keeps released-build records current
    Security test resultsDemonstrate mitigation implementation/effectiveness and retain scope, configuration, findings, and dispositionEngineering / product security retain evidence and retests
    Vulnerability handlingDefine security contact, customer communication, triage, remediation, and local reporting assessmentProduct security and Japanese regulatory functions coordinate response
    User and environment informationAdapt supported configuration, installation, update, and compensating-control instructions for local useManufacturer approves local information and responsibilities

    Reuse accurate architecture, threat, test, and component records from other markets when the product/build matches. Reassess references, scope, labeling, local communication, and application placement. Do not claim a fixed percentage is reusable or that translation alone establishes Japanese conformity.

    SBOM: maintain it and identify it correctly

    The July 2023 Q&A, Q5-6, explains that SBOM creation should be identified in relevant approval/certification applications and the SBOM must be available for presentation, but routine submission of the SBOM itself is not necessary. It is not simply optional evidence.

    Q6 describes component coverage and seven information elements: supplier, component name, version, other unique identifiers, dependency relationships, author of the SBOM data, and timestamp. Check the current source and the applicable application's instructions before choosing fields or attachments. Keep the inventory tied to released software and use it in vulnerability management, not only at application time.

    Existing products and Annex F

    The July 2023 Q&A, Q2, addresses products already marketed and continuing to be manufactured or marketed after April 1, 2024: maintain identifiable internal records covering conformity-notification requirements. Do not assume blanket grandfathering.

    For eligible existing approved, certified, or notified products not developed under JIS T 81001-5-1, Q3 describes use of Annex F for transitional health software. Risk assessment, updated security operating guidance, compensating controls, and partial rewriting may be relevant. The manufacturer must establish the required risk acceptability and identify Annex F use in applicable application materials.

    Annex F is not another calendar extension or a way to avoid cybersecurity responsibilities. Evaluate its actual provisions and applicability using the licensed standard and official Q&A, and retain the assessment and manufacturer approval.

    Security testing and vulnerability response

    Q7 of the July 2023 Q&A says third-party testing is not inherently mandatory when implementation and effectiveness of threat mitigations can be demonstrated. Choose appropriate security testing and independence for the product's risks and evidence needs. A generic network report does not demonstrate every device control.

    For postmarket work, connect vulnerability intake to device/build identification, exploitability assessment, relevant clinical consequences, manufacturer action decisions, and Japanese regulatory reporting assessment. The March 2024 vulnerability-management notification provides an English reference translation; the Japanese original controls. Do not assume every CVE is a reportable adverse event or borrow a different country's reporting clock.

    Worked adaptation example

    This is fictional. A manufacturer has an FDA-oriented cybersecurity file for a connected monitoring device and plans a Japanese configuration with a local service partner.

    Existing recordRequired review before reuse
    Threat model for a remote service interfaceConfirm the Japanese service workflow, access roles, connection method, and attack paths are covered
    Release-specific SBOM and vulnerability assessmentConfirm component coverage and Q&A fields; identify the controlled record and its availability in the relevant application
    Security test reportCheck the marketed build and environment, local interface changes, findings, remediation, and effectiveness evidence
    US vulnerability-management planAdd local contact/customer communication and Japanese reporting decisions; do not replace them with FDA references
    Secure lifecycle proceduresMap to JIS and additional conformity items; document any justified transitional-software approach

    The example is not an approval claim. The manufacturer and its local regulatory partners determine the actual pathway and application content.

    Readiness checklist

    • Establish Article 12(3) applicability and product boundaries.
    • Identify the Japanese pathway and responsible local regulatory parties.
    • Map lifecycle evidence to JIS plus additional notification requirements.
    • Keep the released-build SBOM and vulnerability analysis available and controlled.
    • Verify threat-to-control-to-test traceability and manufacturer risk approval.
    • Evaluate Annex F only where applicable; retain the rationale.
    • Align local operating information, security contacts, and customer communication.
    • Integrate ongoing vulnerability handling and Japanese reporting assessment.

    How Blue Goat Cyber helps

    We support threat modeling, security risk assessment, SBOMs, penetration testing, and cybersecurity evidence adaptation. Japanese applications, QMS approvals, labeling, regulatory reporting, and risk acceptance remain manufacturer responsibilities with the appropriate local regulatory support. Book a discovery call to scope the cybersecurity work without a promised regulatory outcome.

    FAQ

    Are maintenance-only connections outside scope?

    Not automatically. The January 2024 Q&A includes maintenance connections. Assess the actual interfaces and foreseeable access or attack paths.

    Must every application include the full SBOM file?

    No. The July 2023 Q&A distinguishes identifying its creation and maintaining availability from routine attachment. Confirm the applicable pathway and reviewer instructions.

    Is independent penetration testing universally mandatory?

    No. The official Q&A permits demonstration of mitigation implementation and effectiveness without an inherent third-party mandate. Select testing and independence appropriate to the product and evidence needs.

    Does Annex F extend the April 2024 transition?

    No. It is a risk-based transitional-software conformity approach for applicable products, not another grace period.