Blue Goat CyberBlue Goat CyberSMMedical Device Cybersecurity
    K

    510(k) vs De Novo vs PMA vs IDE: cybersecurity comparison

    Dimension 510(k) De Novo PMA IDE
    Statutory/regulatory basis 21 USC 360(k); 21 CFR Part 807, Subpart E. FD&C Act 513(f)(2); 21 CFR Part 860, Subpart D. FD&C Act §515; 21 CFR Part 814. FD&C Act 520(g); 21 CFR Part 812.
    Typical device class Class II (some Class I). Novel low/moderate risk (Class I or II) with no predicate. Class III (high risk, life-supporting/sustaining). Significant-risk investigational devices (any class) entering a clinical study.
    Cybersecurity statutory hook Section 524B applies in full. Section 524B applies in full. Section 524B applies in full. Section 524B(a) does NOT enumerate IDE - it is a marketing-submission statute. Cybersecurity expectations come from the FDA's Feb 3, 2026 final premarket guidance, plus unreasonable-risk-to-subjects review under 21 CFR §812.30(b)(4).
    Cybersecurity submission format eSTAR cybersecurity section (mandatory since Oct 2023). eSTAR cybersecurity section (mandatory since Oct 1, 2025). PMA modular content; cybersecurity package per 2026 guidance. IDE application cybersecurity sections; eCopy or CDRH portal upload (no eSTAR yet).
    Required artifacts (2026 guidance) SPDF documentation, threat model, SBOM, security architecture views, risk assessment, pen test, postmarket plan, labeling. Same seven-section package as 510(k); plus special-controls justification. Same seven-section package; plus deeper architecture, manufacturing, and quality-system evidence. Threat model, security risk assessment, SBOM, architecture views, pen-test evidence sized to investigational risk, mid-study monitoring plan.
    Review clock 90 FDA days (substantive review). 150 FDA days. 180 FDA days; can be longer with panel review. 30 FDA days; the study may begin if FDA does not place it on hold within that window.
    Highest-severity cyber outcome Refuse-To-Accept (RTA) hold - most-cited reason for cyber-driven RTAs. Acceptance-Review hold - checklist mirrors 510(k). Major Deficiency Letter - frequently cites cyber. Clinical Hold under 21 CFR §812.42 - stops enrollment until cybersecurity concerns are resolved.
    Postmarket cyber expectations Postmarket plan + CVD process + SBOM updates. Same as 510(k). Same plus PMA annual reports must address cybersecurity changes. Mid-study security event reporting to investigators / IRB / FDA; IDE supplements for security patches and scope changes.

    Related