Blue Goat CyberBlue Goat CyberSMMedical Device Cybersecurity
    Start here
    Services
    • Medical Device Cybersecurity Consulting
    • FDA Premarket Cybersecurity Package
    • Medical Device Penetration Testing Services
    • FDA Deficiency Response
    • FDA Postmarket Cybersecurity
    • Medical Device Threat Modeling
    • eSTAR Cybersecurity Documentation Support
    See all services
    Products

    Blue Goat products

    • GoatWatch logoGoatWatchSBOM risk management for medical devices
    About
    Resources

    Learn

    • Blog
    • Podcast
    • Webinars
    • Talks & workshops
    • Glossary
    • FAQs

    Playbooks & Tools

    • Guides
    • Playbooks (PDF)
    • Infographics
    • Interactive Tools

    Signals & Proof

    • Goat FeedNew
    • News
    • Medical Device Security News
    • The Goat's Weekly
    • Case Studies
    • Proof / Receipts
    All resources, topic hubs, & collections →
    ⌘K
    Book Strategy SessionHow to prepare →
    Blue Goat Cyber

    Full-service medical device cybersecurity. We protect patients by securing connected medical devices from design through postmarket.

    275+ FDA submissions supported, zero cybersecurity rejections · Mission: 1,000 by 2028

    SDVOSB · Service-Disabled Veteran-Owned Small Business

    We sponsor 10 community projects →

    Services

    • FDA Premarket Cybersecurity Package
    • FDA Deficiency Response
    • Medical Device Threat Modeling
    • Medical Device Penetration Testing Services
    • FDA Postmarket Cybersecurity
    • All services →
    Services
    • FDA Premarket Cybersecurity Package
    • FDA Deficiency Response
    • Medical Device Threat Modeling
    • Medical Device Penetration Testing Services
    • FDA Postmarket Cybersecurity
    • All services →

    Company

    • About
    • Core values
    • Manifesto
    • Leadership
    • Why Us
    • Partners
    • Careers
    • Press
    • Press kit
    • Contact
    • Company overviewPDF
    Company
    • About
    • Core values
    • Manifesto
    • Leadership
    • Why Us
    • Partners
    • Careers
    • Press
    • Press kit
    • Contact
    • Company overviewPDF

    Resources

    • Blog
    • Guides
    • Podcast
    • Case studies
    • Monthly Pulse newsletter
    • All resources →
    Resources
    • Blog
    • Guides
    • Podcast
    • Case studies
    • Monthly Pulse newsletter
    • All resources →

    Get in touch

    • info@bluegoatcyber.com
    • 844-939-GOAT
    • Book a strategy session →
    • 1776 N Scottsdale Rd, Unit 727
      Scottsdale, AZ 85257Serving clients worldwide

    Follow

    © 2026 Blue Goat Cyber. All rights reserved.

    • Privacy
    • Terms
    • Cookies
    • Sitemap
    • Accessibility
    • CVD

    MedTech Cybersecurity · Since 2022

    Goat Feed · Guidance

    InterSystems Corporation InterSystems IRIS for Health

    Successful exploitation of this vulnerability could allow an attacker to view transmitted data and use that data to log into the device.

    Back to the daily feed
    Guidance
    notablePublished October 23, 2026 at 1:00 PM UTC
    Blue Goat take· Blue Goat Cyber Research

    This flaw signifies a lack of encryption for sensitive credentials, enabling attackers to intercept login data in transit. Manufacturers of diagnostic imaging and interoperability platforms using this specific data framework face the highest risk of unauthorized system access. Organizations should verify their current version against the advisory and prioritize risk based remediation to secure data flows.

    Blue Goat analysis

    Scored with Blue Goat's medical device cybersecurity risk methodology: STRIDE classification and CVSS v4.0 exploitability, with a severity-of-harm readout for your own ISO 14971 hazard analysis.

    Reviewed by Christian Espinosa, Founder & CEOOctober 28, 2026

    IRIS for Health is a data platform used for clinical data, interoperability, and health applications. CISA's advisory covers one issue in versions 2026.2.0.221, 2026.1.0.235, and 2025.3.0.226: TLS encryption is turned off by default.

    CVEWhat an attacker can doSTRIDECVSS v4.0 ExploitabilitySecurity impact
    CVE-2026-111594With TLS off by default, an attacker can view transmitted data and use it to log in (CWE-319)Information disclosure, SpoofingHighHigh

    The published vector is network-reachable with no privileges and no user action, so Exploitability reads High. Its Attack Requirements value is "Present," since the attacker has to be positioned on the network path. Blue Goat's method reads Exploitability only from Attack Vector, Privileges Required, and User Interaction, so that doesn't lower the rating. Confidentiality, integrity, and availability impacts are all High. On Blue Goat's security matrix, that's Critical as published.

    The published vectors describe the software, not your device. If the service is reachable only on a segmented clinical network or behind authentication, score your own deployment with the CVSS v4.0 environmental metrics before you rate your risk.

    Severity from your hazard analysisSafety risk at High exploitability
    NegligibleMedium
    Minor or SeriousHigh
    Critical or CatastrophicVery High

    Credentials captured in transit can give an attacker the same access as the account they belong to, including to clinical data.

    What to check now

    1. Check whether your product uses or connects to IRIS for Health in the listed versions.
    2. Check the superserver's TLS setting. InterSystems recommends configuring it to require SSL/TLS. There are three settings: "Disabled" means no TLS, "Enabled" means connections may or may not use TLS, and only "Required" forces TLS on every client connection.
    3. This is a configuration fix, not a version upgrade. Document the setting your product ships with, and include it in your labeling or deployment guidance if customers manage the server.
    4. If you're not affected, record that in a VEX statement with the justification.
    5. Re-score the threat, and carry any patient-harm result into your ISO 14971 file.

    This analysis is informational. It is based on CISA's published advisory and does not assess any specific manufacturer's device.

    Related Goat Feed analysis

    Other items reviewed by the Blue Goat team.

    • Thermo Fisher Torrent Suite Software
    • Fourth Frontier Frontier X Mobile Application, Frontier X2
    • Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT
    • Thermo Fisher Applied Biosystems Genetic Analyzers
    Citations
    • CISA ICS Medical Advisories
    • Methodology and sources →
    #icsma#advisory
    Need help acting on this?

    Talk to Blue Goat Cyber

    Penetration testing, SBOM, threat modeling, and 524B submission support for MedTech.

    Talk to usSee services