Blue Goat CyberBlue Goat CyberSMMedical Device Cybersecurity
    Start here
    Services
    • Medical Device Cybersecurity Consulting
    • FDA Premarket Cybersecurity Package
    • Medical Device Penetration Testing Services
    • FDA Deficiency Response
    • FDA Postmarket Cybersecurity
    • Medical Device Threat Modeling
    • eSTAR Cybersecurity Documentation Support
    See all services
    Products

    Blue Goat products

    • GoatWatch logoGoatWatchSBOM risk management for medical devices
    About
    Resources

    Learn

    • Blog
    • Podcast
    • Webinars
    • Talks & workshops
    • Glossary
    • FAQs

    Playbooks & Tools

    • Guides
    • Playbooks (PDF)
    • Infographics
    • Interactive Tools

    Signals & Proof

    • Goat FeedNew
    • News
    • Medical Device Security News
    • The Goat's Weekly
    • Case Studies
    • Proof / Receipts
    All resources, topic hubs, & collections →
    ⌘K
    Book Strategy SessionHow to prepare →
    Blue Goat Cyber

    Full-service medical device cybersecurity. We protect patients by securing connected medical devices from design through postmarket.

    275+ FDA submissions supported, zero cybersecurity rejections · Mission: 1,000 by 2028

    SDVOSB · Service-Disabled Veteran-Owned Small Business

    We sponsor 10 community projects →

    Services

    • FDA Premarket Cybersecurity Package
    • FDA Deficiency Response
    • Medical Device Threat Modeling
    • Medical Device Penetration Testing Services
    • FDA Postmarket Cybersecurity
    • All services →
    Services
    • FDA Premarket Cybersecurity Package
    • FDA Deficiency Response
    • Medical Device Threat Modeling
    • Medical Device Penetration Testing Services
    • FDA Postmarket Cybersecurity
    • All services →

    Company

    • About
    • Core values
    • Manifesto
    • Leadership
    • Why Us
    • Partners
    • Careers
    • Press
    • Press kit
    • Contact
    • Company overviewPDF
    Company
    • About
    • Core values
    • Manifesto
    • Leadership
    • Why Us
    • Partners
    • Careers
    • Press
    • Press kit
    • Contact
    • Company overviewPDF

    Resources

    • Blog
    • Guides
    • Podcast
    • Case studies
    • Monthly Pulse newsletter
    • All resources →
    Resources
    • Blog
    • Guides
    • Podcast
    • Case studies
    • Monthly Pulse newsletter
    • All resources →

    Get in touch

    • info@bluegoatcyber.com
    • 844-939-GOAT
    • Book a strategy session →
    • 1776 N Scottsdale Rd, Unit 727
      Scottsdale, AZ 85257Serving clients worldwide

    Follow

    © 2026 Blue Goat Cyber. All rights reserved.

    • Privacy
    • Terms
    • Cookies
    • Sitemap
    • Accessibility
    • CVD

    MedTech Cybersecurity · Since 2022

    Goat Feed · Guidance

    J4Care dcm4che

    Successful exploitation of these vulnerabilities could allow an attacker to delete stored medical images, disclose patient information, inject forged studies, reassign patient records, overwrite files, and cause a denial-of-service condition.

    Back to the daily feed
    Guidance
    notablePublished October 16, 2026 at 1:00 PM UTC
    Blue Goat take· Blue Goat Cyber Research

    Critical flaws in this DICOM archive allow unauthorized parties to manipulate or delete clinical imaging data, risking diagnostic integrity. Medical device makers using dcm4chee for PACS integration or cloud storage are most vulnerable to these high severity exploits. Teams must immediately audit software bills of materials for affected versions and apply patches to prevent potential patient record corruption.

    Blue Goat analysis

    Scored with Blue Goat's medical device cybersecurity risk methodology: STRIDE classification and CVSS v4.0 exploitability, with a severity-of-harm readout for your own ISO 14971 hazard analysis.

    Reviewed by Christian Espinosa, Founder & CEOOctober 28, 2026

    The dcm4chee-arc-light archive is an open-source PACS used to store and serve medical images. CISA's advisory covers six vulnerabilities in version 5.35.1. Two of them go beyond data exposure: they let an unauthenticated attacker change which patient a study belongs to.

    CVEWhat an attacker can doSTRIDECVSS v4.0 ExploitabilitySecurity impact
    CVE-2026-105667In the default configuration, the HL7 listener accepts patient-merge messages (ADT^A40) without authenticating the sender, so a remote sender can reassign studies and related workflow records (CWE-306)Spoofing, TamperingHighHigh
    CVE-2026-105279In the default configuration, the archive accepts DICOM associations from unregistered callers, who can retrieve patient information and images, and file fabricated study content under an existing patient identity (CWE-306)Spoofing, Tampering, Information disclosureHighHigh
    CVE-2026-97851A storage REST service lets locations still holding DICOM instances be moved to deletion states. The purge scheduler then deletes the stored object while the database still lists the instance (CWE-862)Tampering, Denial of serviceHighHigh
    CVE-2026-107621A crafted or truncated JPEG stream can put the parser into an infinite loop (CWE-835)Denial of serviceHighHigh
    CVE-2026-105273A malformed MP4 box can stall parsing indefinitely (CWE-835)Denial of serviceHighHigh
    CVE-2026-101021Crafted multipart input forces excessive processing (CWE-407)Denial of serviceHighHigh

    All six published vectors are network-reachable with no privileges and no user action, so Exploitability reads High. Each has at least one High impact. On Blue Goat's security matrix, all six are Critical as published.

    The published vectors describe the software, not your device. If the service is reachable only on a segmented clinical network or behind authentication, score your own deployment with the CVSS v4.0 environmental metrics before you rate your risk.

    Severity from your hazard analysisSafety risk at High exploitability
    NegligibleMedium
    Minor or SeriousHigh
    Critical or CatastrophicVery High

    The two default-configuration flaws matter most clinically. A study filed under the wrong patient, or fabricated content attached to a real one, puts incorrect data in front of a clinician. The purge flaw can leave the archive listing images that no longer exist.

    What to check now

    1. Search your SBOM for dcm4chee-arc-light 5.35.1, or any product built on it.
    2. Check your configuration against the two default-configuration flaws: whether unregistered calling AE titles are accepted, and whether the HL7 listener authenticates senders.
    3. Update to release 5.35.2 or later, which J4Care recommends.
    4. If you're not affected, record that in a VEX statement with the justification.
    5. Re-score each affected threat, and carry patient-harm results into your ISO 14971 file.

    This analysis is informational. It is based on CISA's published advisory and does not assess any specific manufacturer's device.

    Related Goat Feed analysis

    Other items reviewed by the Blue Goat team.

    • Thermo Fisher Torrent Suite Software
    • Fourth Frontier Frontier X Mobile Application, Frontier X2
    • Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT
    • Thermo Fisher Applied Biosystems Genetic Analyzers
    Citations
    • CISA ICS Medical Advisories
    • Methodology and sources →
    #icsma#advisory
    Need help acting on this?

    Talk to Blue Goat Cyber

    Penetration testing, SBOM, threat modeling, and 524B submission support for MedTech.

    Talk to usSee services