Threat Modeling for Cardiovascular Devices
Threat models for pacemakers, ICDs, monitors, and remote-follow cloud - STRIDE/TARA traced to ISO 14971 hazards. Programmer, telemetry, and backhaul covered.
Aligned to FDA's February 3, 2026 premarket cybersecurity guidance.
Cardiac device threat models have to span a multi-decade deployed lifetime and four distinct compute elements: implant, in-clinic programmer, home monitor, and cloud follow-up service. Cardiac implant advisories have shown how a home monitor can become a path to an implant, so a threat model in this segment should treat the home monitor as its own trust boundary. We deliver STRIDE-per-element threat models that treat each of those four elements as a separate trust domain, model the data flows between them, and trace every identified threat to an ISO 14971 hazard and a risk control.
We model the programmer↔implant interface for spoofing, tampering, and elevation-of-privilege at the protocol level. We model the home monitor as 'attacker-controlled' explicitly - what can it do beyond passive telemetry relay? - because that's the real-world incident pattern. We model the cellular/Wi-Fi backhaul for MITM and impersonation, and the cloud APIs for tenant isolation and broken authorization. Crucially for this segment, we layer in a postmarket threat model: how does the threat landscape change when a CVE drops on a library that's deployed in a million implants you cannot recall? The output is an AAMI SW96 + AAMI TIR97 aligned threat document that lands in eSTAR cleanly and gives your postmarket team something to operate from.
Layers we exercise in this engagement
The cardiovascular system, from the outermost cloud and clinician surfaces down to the device itself. Highlighted layers are exercised by this medical device threat modeling.
- 01Clinician portal Tested
- 02Cloud APIs Tested
- 03Home monitor Tested
- 04RF telemetry Tested
- 05In-clinic programmer Tested
- 06Implant firmware Tested
Layers shown outermost (top) to innermost (bottom). Dashed rows are part of the surrounding system but out of scope for this view.
Medical Device Threat Modeling engagement, end to end
Four phases, fixed fee, scoped to cardiovascular architecture from kickoff onward.
- 01
Design intake
DFD3 data flow diagrams, trust boundaries, numbered entry points, and an Entry Point Descriptions table prepared from your design inputs.
- 02
STRIDE analysis and attack trees
Threat classification per in-scope element, with confidentiality, integrity, and availability attack trees. STRIDE classifies threats; it does not score them.
- 03
Threat Table and traceability
Threat IDs, initial risk, named controls, applicable test-case IDs, and manufacturer-supplied patient-harm context. Residual risk belongs in the separately scoped cybersecurity risk assessment.
- 04
Threat-model handoff
Threat model and Threat Table prepared for the applicable eSTAR attachments. The Global System, Multi-Patient Harm, Updatability and Patchability, and Security Use Case security architecture views are separate, separately scoped and priced deliverables. Testing and broader SPDF documentation are separate work items.
What we see in Cardiovascular medical device threat modeling
The patterns we hit in this segment, this service, again and again.
Home monitor not modeled as attacker-controlled
Threat model assumes home monitor is a trusted relay. No documented answer for the home-monitor-as-path scenario.
Cloud follow-up tenant isolation not in scope
Cloud architecture diagram treats all clinics as one trust domain. STRIDE-per-element on the cloud APIs not performed.
Postmarket scenarios absent
Threat model covers as-shipped device. CVE-on-deployed-fleet, signing-infra compromise, and update-path tampering not analyzed.
Programmer-side credential compromise not modeled
Programmer treated as trusted endpoint. Compromised programmer / stolen programmer scenarios absent.
"Blue Goat's knowledge of regulatory requirements versus cybersecurity challenges was highly valuable and readily apparent as we were guided by and worked alongside their team towards the development of a comprehensive and compliant cybersecurity plan for our new medical device. Especially helpful for our company as we are a startup. Their team and competencies nicely filled our resource needs. Thank you Blue Goat!"

Standard Medical Device Threat Modeling deliverables
The same deliverables the parent Medical Device Threat Modeling service ships with - tuned to your cardiovascular architecture.
- ANSI/AAMI SW96 + ISO 14971 alignment
- Full medical device system coverage
- Threat-to-mitigation traceability
- Justified methodology and assumptions
What lands in your eSTAR submission
Documents structured for the cybersecurity attachments of your submission - no reformatting on your side.
- ANSI/AAMI SW96 + ISO 14971 alignment
- Full medical device system coverage
- Threat-to-mitigation traceability
- Justified methodology and assumptions
Standards that apply
The Cardiovascular baseline, plus the call-outs that matter for medical device threat modeling in this segment.
Segment-specific call-outs
AAMI TIR60601-4-5 + AAMI TIR97
Threat model must reference them in the standards-applied section.
FDA postmarket cyber guidance
Postmarket scenarios are required for implant threat models - not optional for this segment.
What's not in scope
We scope tightly on purpose. These items are either out-of-scope by design or belong in a separate engagement - we'll tell you up front, not after kickoff.
- Penetration testing execution (scoped separately)
- Clinical risk analysis under ISO 14971 (we feed it, we do not own it)
- Hospital network architecture review
Medical Device Threat Modeling for Cardiovascular - FAQs
The questions buyers in this segment actually ask before scoping a medical device threat modeling engagement.
Go deeper on Cardiovascular and premarket
A practical, ungated buyer's guide for medical device manufacturers evaluating cybersecurity partners, what goes wrong, why it costs you, and what to demand from your next engagement. Aligned to the FDA February 2026 premarket guidance.
The most common high- and critical-severity findings we surface in medical device penetration tests, what each one looks like in the field, and how to fix it before your FDA submission.
A practical, ungated guide to the threat modeling gaps that trigger FDA cybersecurity questions in 510(k), De Novo, and PMA submissions - and exactly how to close them before reviewers find them.
Medical device remote access security needs named users, bounded privileges, session records, and clinical safeguards. Review service and remote testing paths.
Cybersecurity for small hospitals starts with device inventories, safe remote access, downtime plans, and manufacturer evidence. Separate HHS and FDA roles.
FDA MDDT for cybersecurity: what the qualified MITRE CVSS rubric is, how medical device makers use it to score vulnerabilities, and where its limits are.
Other engagements for Cardiovascular
Teams in this segment commonly bundle these alongside medical device threat modeling.
Keep going
Cybersecurity alerts and guides
Goat's Weekly alerts
Medical device advisories and safety communications, with links to original sources. An alert is a reason to assess applicability, not proof that your device is affected.
Threat modeling, eSTAR 7.1, and SBOM evidence
Connect threats to controls and test evidence. Compare the CISA 2026 SBOM fields with the NTIA 2021 baseline the FDA still cites, plus its support fields. Guidance recommendations remain separate from statutory duties.
Threat modeling scope
What is in a threat modeling engagement?
Included work is defined in the signed proposal. These scope options are not automatic inclusions in every engagement.
Fixed-fee deliverables
- A threat model with DFD3 data flow diagrams, system elements, trust boundaries, and numbered entry points.
- An Entry Point Descriptions table, STRIDE analysis per in-scope element, and confidentiality, integrity, and availability attack trees.
- A Threat Table with Threat IDs, initial risk, named controls, and traceability to applicable test-case IDs and manufacturer-supplied patient-harm context.
- Threat model and Threat Table documentation prepared for the applicable eSTAR cybersecurity attachments. Test execution and the residual cybersecurity risk assessment are separate deliverables.
Required inputs
- System architecture, interface list, intended use, and the device versions in scope. Include connected mobile apps, cloud APIs, update paths, and external dependencies where applicable.
- Existing risk management file, manufacturer-defined harm severity and acceptance criteria, and any prior threat model.
- Access to engineers who can answer design questions.
Exclusions and separate work
- Global System, Multi-Patient Harm, Updatability and Patchability, and Security Use Case architecture views are separately scoped and priced.
- Residual cybersecurity risk assessment, penetration test execution, SBOM work, and broader SPDF documentation are separate work items.
- General software verification and validation, clinical performance testing, and full QMS implementation or certification are outside Blue Goat's product cybersecurity scope.
- The manufacturer retains engineering changes, clinical-risk evaluation, risk acceptance, release approval, and regulatory submission decisions. No regulatory outcome is promised.
Pricing and scope changes
Fixed fee, quoted after a scoping call. Scope depends on the number of interfaces and system elements. The Global System, Multi-Patient Harm, Updatability and Patchability, and Security Use Case security architecture views are not included in standalone threat modeling. They are scoped and priced separately. A broader premarket engagement can include both as distinct deliverables when the proposal specifies them. Risk acceptance remains a documented manufacturer decision. A written fixed-fee quote after scoping. The proposal names deliverables, versions, assumptions, required inputs, exclusions, and agreed dates. Additional work requires a separately agreed scope change. Missing inputs, access restrictions, manufacturer fixes, and review feedback can affect delivery.
Scope a Medical Device Threat Modeling engagement for your cardiovascular program.
A 30-minute discovery call with Christian Espinosa, Founder and CEO, and Kristy Kennedy, VP of Sales.