Premarket · NeuroTech / BCI

    Threat Modeling for NeuroTech & BCIs

    Threat models for BCIs, DBS, and closed-loop neuromodulation - STRIDE/TARA traced to ISO 14971, with implant, programmer, and patient-app trust boundaries.

    Aligned to FDA's February 3, 2026 premarket cybersecurity guidance.

    How this applies to NeuroTech / BCI

    NeuroTech threat modeling has to handle a system with three distinct trust domains - implant, clinician programmer, patient-side companion - and a closed-loop control path inside the implant itself. Apply STRIDE per data flow across all of those boundaries, not a single block diagram with a few arrows. Our threat models for this segment use STRIDE-per-element on a system data-flow diagram that includes the in-implant sense-stim loop as a first-class boundary, then trace each identified threat to a risk control in your ISO 14971 file and an SPDF mitigation.

    We model the wireless link to the implant explicitly: pairing, session, command authorization, and parameter-write authorization as separate controls. We model the patient app as compromised by default and verify that no implant control depends on app-side enforcement. We model the clinician programmer as both a trusted clinician tool and a potentially stolen device, and demand differentiated controls for each. For closed-loop systems we add a control-integrity threat-modeling pass: which elements of the sense-to-stim pipeline can be tampered with, and what is the patient-harm scenario if they are? Output is an AAMI SW96-aligned threat model document that maps to your hazard analysis, plus the global system view that FDA guidance recommends for connected devices.

    For brain-computer interfaces (BCIs) we add BCI-specific elements to the model. Neural recordings are treated as a sensitive asset that cannot be changed once exposed. Decoded output to an external device, such as a cursor, speller, or prosthetic, is modeled as its own data flow. The inductive charging and telemetry link, research data exports, and multi-vendor interfaces between sensors, processors, and stimulators each get their own STRIDE pass. Each threat traces to a patient-harm scenario in your ISO 14971 file.

    Attack surface

    Layers we exercise in this engagement

    The neurotech / bci system, from the outermost cloud and clinician surfaces down to the device itself. Highlighted layers are exercised by this medical device threat modeling.

    1. 01Cloud APIs Tested
    2. 02Patient remote Tested
    3. 03Clinician programmer Tested
    4. 04Wireless link Tested
    5. 05Implant firmware Tested
    6. 06Closed-loop sensing Tested

    Layers shown outermost (top) to innermost (bottom). Dashed rows are part of the surrounding system but out of scope for this view.

    How the engagement runs

    Medical Device Threat Modeling engagement, end to end

    Four phases, fixed fee, scoped to neurotech / bci architecture from kickoff onward.

    1. 01

      Design intake

      DFD3 data flow diagrams, trust boundaries, numbered entry points, and an Entry Point Descriptions table prepared from your design inputs.

    2. 02

      STRIDE analysis and attack trees

      Threat classification per in-scope element, with confidentiality, integrity, and availability attack trees. STRIDE classifies threats; it does not score them.

    3. 03

      Threat Table and traceability

      Threat IDs, initial risk, named controls, applicable test-case IDs, and manufacturer-supplied patient-harm context. Residual risk belongs in the separately scoped cybersecurity risk assessment.

    4. 04

      Threat-model handoff

      Threat model and Threat Table prepared for the applicable eSTAR attachments. The Global System, Multi-Patient Harm, Updatability and Patchability, and Security Use Case security architecture views are separate, separately scoped and priced deliverables. Testing and broader SPDF documentation are separate work items.

    Common findings

    What we see in NeuroTech / BCI medical device threat modeling

    The patterns we hit in this segment, this service, again and again.

    • Stolen-programmer scenario absent from threat file

      Programmer modeled only as 'clinician in clinic'. Stolen-device, lost-device, and after-hours scenarios left unanalyzed.

    • Closed-loop sense path treated as trusted

      Sense-to-stim path inside implant assumed trusted. Bench fault-injection scenarios not in scope of threat model.

    • Patient-app compromise not assumed

      Implant authorization model trusts app's representation of user identity. Rooted-device threat scenario missing.

    • Neural data treated like ordinary telemetry

      Neural recordings modeled as routine device logs. Research exports, cloud retention, and re-identification risk left unanalyzed.

    • Decoded BCI output missing from the data-flow diagram

      Path from decoder to external assistive device not drawn. Spoofed or replayed intent commands never enumerated as threats.

    • Postmarket update path not threat-modeled

      Update channel assumed safe because 'signed firmware'. Threat model doesn't cover compromise of the signing infra or rollback attacks.

    Related reading

    NeuroTech / BCI reading and listening

    "Blue Goat's niche expertise in FDA-facing cybersecurity made all the difference. Their reports were built with the FDA's expectations in mind; it gave us confidence that we were submitting exactly what reviewers want to see."
    Scott Odland
    Scott Odland
    Solutions Architect · Rhaeos
    What you get

    Standard Medical Device Threat Modeling deliverables

    The same deliverables the parent Medical Device Threat Modeling service ships with - tuned to your neurotech / bci architecture.

    • ANSI/AAMI SW96 + ISO 14971 alignment
    • Full medical device system coverage
    • Threat-to-mitigation traceability
    • Justified methodology and assumptions
    Deliverable preview

    What lands in your eSTAR submission

    Documents structured for the cybersecurity attachments of your submission - no reformatting on your side.

    • ANSI/AAMI SW96 + ISO 14971 alignment
    • Full medical device system coverage
    • Threat-to-mitigation traceability
    • Justified methodology and assumptions
    Standards

    Standards that apply

    The NeuroTech / BCI baseline, plus the call-outs that matter for medical device threat modeling in this segment.

    FDA 2026 Premarket Cyber Guidance
    AAMI SW96
    ISO 14971
    IEC 62304
    IEC 81001-5-1
    ISO/IEC 27001

    Segment-specific call-outs

    ANSI/AAMI SW96 + ISO 14971 traceability

    Every threat must trace to a risk control. We deliver a traceable threat-to-control matrix.

    AAMI TIR97 (postmarket)

    For implantables, the threat model must include the postmarket update and CVD pathways, not just the as-shipped device.

    Honest scoping

    What's not in scope

    We scope tightly on purpose. These items are either out-of-scope by design or belong in a separate engagement - we'll tell you up front, not after kickoff.

    • Penetration testing execution (scoped separately)
    • Clinical risk analysis under ISO 14971 (we feed it, we do not own it)
    • Hospital network architecture review
    FAQs

    Medical Device Threat Modeling for NeuroTech / BCI - FAQs

    The questions buyers in this segment actually ask before scoping a medical device threat modeling engagement.

    Related reading

    Go deeper on NeuroTech / BCI and premarket

    Pair this with

    Other engagements for NeuroTech / BCI

    Teams in this segment commonly bundle these alongside medical device threat modeling.

    Keep going

    Cybersecurity alerts and guides

    Goat's Weekly alerts

    Medical device advisories and safety communications, with links to original sources. An alert is a reason to assess applicability, not proof that your device is affected.

    Threat modeling, eSTAR 7.1, and SBOM evidence

    Connect threats to controls and test evidence. Compare the CISA 2026 SBOM fields with the NTIA 2021 baseline the FDA still cites, plus its support fields. Guidance recommendations remain separate from statutory duties.

    Threat modeling scope

    What is in a threat modeling engagement?

    Included work is defined in the signed proposal. These scope options are not automatic inclusions in every engagement.

    Fixed-fee deliverables

    • A threat model with DFD3 data flow diagrams, system elements, trust boundaries, and numbered entry points.
    • An Entry Point Descriptions table, STRIDE analysis per in-scope element, and confidentiality, integrity, and availability attack trees.
    • A Threat Table with Threat IDs, initial risk, named controls, and traceability to applicable test-case IDs and manufacturer-supplied patient-harm context.
    • Threat model and Threat Table documentation prepared for the applicable eSTAR cybersecurity attachments. Test execution and the residual cybersecurity risk assessment are separate deliverables.

    Required inputs

    • System architecture, interface list, intended use, and the device versions in scope. Include connected mobile apps, cloud APIs, update paths, and external dependencies where applicable.
    • Existing risk management file, manufacturer-defined harm severity and acceptance criteria, and any prior threat model.
    • Access to engineers who can answer design questions.

    Exclusions and separate work

    • Global System, Multi-Patient Harm, Updatability and Patchability, and Security Use Case architecture views are separately scoped and priced.
    • Residual cybersecurity risk assessment, penetration test execution, SBOM work, and broader SPDF documentation are separate work items.
    • General software verification and validation, clinical performance testing, and full QMS implementation or certification are outside Blue Goat's product cybersecurity scope.
    • The manufacturer retains engineering changes, clinical-risk evaluation, risk acceptance, release approval, and regulatory submission decisions. No regulatory outcome is promised.

    Pricing and scope changes

    Fixed fee, quoted after a scoping call. Scope depends on the number of interfaces and system elements. The Global System, Multi-Patient Harm, Updatability and Patchability, and Security Use Case security architecture views are not included in standalone threat modeling. They are scoped and priced separately. A broader premarket engagement can include both as distinct deliverables when the proposal specifies them. Risk acceptance remains a documented manufacturer decision. A written fixed-fee quote after scoping. The proposal names deliverables, versions, assumptions, required inputs, exclusions, and agreed dates. Additional work requires a separately agreed scope change. Missing inputs, access restrictions, manufacturer fixes, and review feedback can affect delivery.

    Medical Device Threat Modeling · NeuroTech / BCI

    Scope a Medical Device Threat Modeling engagement for your neurotech / bci program.

    A 30-minute discovery call with Christian Espinosa, Founder and CEO, and Kristy Kennedy, VP of Sales.